C004387_07_CR3500_ User_Manual - 47
Save Settings
CR3500 has a baery-powered real me clock embedded in the reader. When enabled, the me stamp will be a prex to the data.
Time stamping connues unl disabled. The me stamp will be shown in the following format: YYYY-MM-DD HH:MM:SS
On O (Default)
Note: Turning on the me stamp feature will cause the reader to re-start. Make sure previous sengs have been saved prior to
scanning the code or you will lose unsaved sengs.
4.9 - Time Stamp Sengs
This mode can be used to establish a permanent connecon between the reader and a CodeXML® modem,
Prepare the reader to communicate in ‘RF Comm Mode’ by scanning the QuickConnect code on the paired modem to which you wish
to establish a permanent link. Listen for the single beep to verify the connecon acknowledgement. Scan the Lockout Link Mode code
(see below). Set appropriate meout sengs, if applicable (see Secon 1.4.5).
To reassign a permanent connecon to a dierent reader, scan the unlock link code. Using the ‘new’ reader’ follow the direcons
outlined in the previous paragraph.
Lockout Link Mode Unlock Link Mode
4.10 - Lock-out Link Mode